Cables buried in a wall should run straight up, down or across from a socket or switch, or close to the ceiling and the corners. Pipes and cables can still be hidden behind any wall, so use a cable and pipe detector first. Before you start, find the stop tap, the gas shut-off and the fuse box, and get the underfloor heating layout if you have it.

The short version

Find these before you drill

  • Find the stop tap, and check it turns.
  • Find the outside stop valve. Usually under a small cover on the path.
  • Find the gas shut-off handle, usually near the gas meter.
  • Find the consumer unit and its main switch.
  • Get the underfloor heating layout, if you have underfloor heating.

Then

  • Mark the cable zones on the wall.
  • Run a cable and pipe detector over the spot.
  • Use the right fixings for the wall.
  • Check the meter boxes outside are fixed and sealed.

The detail, for reading before you go

Where do cables run in walls in the UK?

In set zones. The IET, which publishes the UK wiring regulations, sets out where a cable buried less than 50mm into a wall may run without mechanical protection. It can run straight up, down or across to a socket, switch or light point. It can also run within 150mm of the top of the wall, or within 150mm of a corner. Electrical Safety First gives the same advice to people doing DIY: buried cables should run horizontally or vertically from sockets and switches.

The zones carry through thin walls. If a wall is 100mm thick or less, a socket on one side creates a zone on the other side too. So check both sides before drilling an inside wall.

The zones tell you where cables are likely to be. They don't make the rest of the wall safe. Cables can run outside the zones if they have other kinds of protection, such as an earthed metal covering or metal conduit. Cables buried less than 50mm deep without that protection should also be protected by an RCD, a safety switch in the consumer unit. That cuts the risk of a shock, but it doesn't stop you drilling through a cable.

A trick we used a rough sketch of each wall before drilling. We marked the sockets, switches and light points, shaded the zones in pencil, and only drilled outside them.

Where are pipes in walls?

Assume they could be behind any wall. The NHQB warns that pipes and electrical cables may be hidden behind walls, and says to use a cable and pipe detector before drilling or fixing anything.

Stud walls (plasterboard on a frame) are hollow, and services can pass through them. Knauf's installer manual for its plasterboard walls includes details for pipes running through them. Where a wall is built on metal studs, the RCD rule applies to cables inside it at any depth.

Floors and lofts hide services too. The NHQB says loft spaces may contain pipework, electrical cables or ventilation, and to take care not to damage them. NHBC's standards for builders also expect any services under a wood floor finish to be tested before the floor goes down.

How can I tell if water pipes are behind a wall?

Use a cable and pipe detector, as the NHQB suggests. Electrical Safety First says a good-quality detector can help track buried cables before you start work.

It also says to shut off the power for DIY close to electrics. If you hit a water pipe, turn the water off at the stop tap.

Underfloor heating pipes

Underfloor heating pipes are hidden in the floor. NHBC Foundation guidance for builders says this makes them potentially vulnerable to puncture from later work that involves screwing or drilling into the floor. It says the installer must clearly and accurately communicate the layout. Its example is pipe loops running under a toilet, where fixing screws too close to the loops could cause a leak.

Ask the builder for the layout before you fix anything to the floor: a door stop, a new toilet or a fitted wardrobe. The heating page covers how to run it.

Can I get drawings of what's behind the walls?

Ask, but don't expect a full map. Three documents come close.

  • The health and safety file. The builder must give you one at completion. HSE guidance says it should consider including where significant services run, and as-built drawings.
  • The heating and ventilation instructions should show where each system is, on a floor plan.
  • You should get the builder's photos of the build quality. They show insulation, not cables.

The builder doesn't have to let you visit during the build. If it does, it must tell you what safety precautions to take.

The stop tap and the outside stop valve

Thames Water says the inside stop valve, also called the stopcock or stop tap, is usually just after the water pipe comes into the house. Common places are under the kitchen sink, in an airing cupboard, under the stairs or in the garage. It suggests checking every month that it still works.

The outside stop valve is usually under a cover on the path or the road, sometimes near the water meter. Thames Water says to use it only in an emergency, and you may need a special key to turn it.

Gas and electricity meters

Know how to turn off the gas. Cadent says the shut-off handle is usually near the gas meter and turns 90 degrees. If you or your builders hit a gas pipe, National Gas says to call the National Gas Emergency Service on 0800 111 999, day or night.

Not everything in the electricity meter box is yours. GTC, a network operator, explains that it is responsible for the incoming service cable and the cut-out (the box that cable runs into). The meter belongs to your energy supplier, and only your supplier can remove the main fuse.

The official checklist expects meter boxes outside to be securely fixed, level and clean, with the pipework sealed where it goes in. If they're not, add it to your snag list and report it to the builder.

What you own, and what the water company or network owns

Water. Ofwat says the water company looks after the mains and the pipe up to your property boundary. From there, the supply pipe into your home is usually yours, along with any stop taps on it. Thames Water adds that all your internal pipes, appliances and fittings are yours. There can be exceptions, so Ofwat suggests checking with your water company and your deeds.

Gas. Cadent, one of the gas networks, looks after the pipes in the street and up to your meter. Your supplier is responsible for the meter. The pipes from the meter to your boiler and cooker are yours.

Electricity. GTC says the network operator is responsible for the service cable and cut-out, and the supplier owns the meter. The consumer unit is part of your own wiring, to be looked after by a qualified electrician.

Will drilling affect my warranty?

It can. Premier Guarantee says damage caused by DIY or maintenance is unlikely to be covered by its policy. It also warns that building over water or gas pipes, or electricity or telephone cables, could damage them. Pipes and cables on your side of the boundary or meter are yours to repair, as above.

From our own build

We had our cameras and doorbell fitted by an installer, who checked behind each spot before drilling.

Our builder gave us some plans without our asking, but few electrical drawings and nothing showing what runs behind the walls. We had an inspection during the build, before the plaster went up, and took lots of photos, so we can still see what's in the walls.

Where this comes from

Every fact on this page comes from the documents below. Anything marked ‘a trick we used’ is our own.

Official and industry guidance

  1. Thames Water, Find and use your inside stop valve, web page, retrieved 9 October 2026
  2. Thames Water, How to find and use your outside stop valve, web page, retrieved 9 October 2026
  3. Cadent, What to do if you smell gas, web page, retrieved 9 October 2026
  4. Electrical Safety First, RCDs explained, web page, retrieved 9 October 2026
  5. NHBC Foundation, Underfloor heating: a guide for house builders (NF71), September 2016, p.4
  6. The IET (IEE Wiring Matters), Requirements for cables concealed in a wall or partition - A brief overview, Summer 2008, p.2, p.4
  7. New Homes Quality Board, A guide to settling into your new home, June 2026, p.11, p.12
  8. New Homes Quality Board, Pre-Completion Inspection Checklist: House, Version 2, March 2026, p.18
  9. Electrical Safety First, Electrical Safety Advice for DIY-ers, web page, retrieved 9 October 2026
  10. The IET, Change to requirements for RCD protection of cables concealed in walls or partitions, January 2015 (BS 7671:2008+A3:2015)
  11. Knauf, Knauf Partitions (drywall partitions manual), PDF created 6 June 2024 (no printed date), p.18
  12. NHBC, NHBC Standards 2026, Chapter 9.3: Floor finishes (copy published by New Build Inspections), 2026, 9.3.6
  13. New Homes Quality Board, New Homes Quality Code, Version 2, March 2026, 2.8, 2.11
  14. Consumer Code for Home Builders, Code requirements and good practice guidance, fifth edition, January 2024, 4.1.1
  15. legislation.gov.uk, The Construction (Design and Management) Regulations 2015, SI 2015/51, revised version with no outstanding changes, retrieved 15 October 2026, reg 4(7)
  16. Health and Safety Executive, Managing health and safety in construction: Construction (Design and Management) Regulations 2015, Guidance on Regulations (L153), 2015, p.81
  17. Ministry of Housing, Communities and Local Government, Approved Document L: Conservation of fuel and power, Volume 1: Dwellings, 2021 edition incorporating 2023 amendments, 2021 edition, February 2023 amendments, 9.2, 9.3, B7
  18. National Gas, Emergency contacts, web page, retrieved 9 October 2026
  19. GTC, A typical electric domestic set-up: understanding what's what and who does what, PDF created 28 April 2026 (no printed date), p.2
  20. Ofwat, Responsibility for pipes and pumping stations, web page, retrieved 9 October 2026
  21. Thames Water, Pipe responsibility, web page, retrieved 9 October 2026
  22. Cadent, Got an engineer coming, web page, retrieved 9 October 2026
  23. Premier Guarantee, Home maintenance tips, undated, retrieved October 2026

Last checked 15 October 2026

For general education only. It isn't legal or surveying advice. Always check your own warranty documents and Code version, and speak to your housebuilder, your warranty provider or a qualified snagging inspector before relying on it. Read the disclaimer.